Quick Answer
Calculate NEC 690.7(c) PV String Voltage Correction for Lowest Expected Ambient Temperature
Calculator
Need Equipment or a Supplier for This Project?
Use your calculation result to continue with equipment selection, supplier discovery, engineering support, or project evaluation.
Find Engineering Solutions →Result Interpretation
NEC 690.7(c) PV String Voltage Correction for Lowest Expected Ambient Temperature calculator computes Maximum DC String Voltage in V using the defined engineering formula and the input values provided. Maximum DC String Voltage is expressed in V. No universal acceptance threshold is defined by this calculator.
Worked Example
Verified calculation
Given:
- Open-Circuit Voltage at STC = 40
- Temperature Coefficient of Voc = -0.12
- Record Low Ambient Temperature = -25
- STC Temperature = 25
- Number of Modules in Series = 12
Expected Result:
- Maximum DC String Voltage = 3360
Engineering Interpretation:
Under the given input conditions, the calculated result is: Maximum DC String Voltage = 3360 V.
The actual numerical result is computed by the Runtime engine using the persisted tool definition. The values shown here come from deterministically validated test cases.
Formula / Method
maximum dc string voltage = open-circuit voltage at stc * (1 + (temperature coefficient of voc * (record low ambient temperature - stc temperature))) * number of modules in seriesFormula family: formula_solar_pv_array_dc_string_voltage_calculation_per_nec_6907c
Variables
| Symbol | Label | Role | Description |
|---|---|---|---|
| voc_stc | Open-Circuit Voltage at STC | INPUT | Open-Circuit Voltage at STC |
| temp_coeff_voc | Temperature Coefficient of Voc | INPUT | Temperature Coefficient of Voc |
| low_temp | Record Low Ambient Temperature | INPUT | Record Low Ambient Temperature |
| t_stc | STC Temperature | INPUT | STC Temperature |
| num_modules_in_series | Number of Modules in Series | INPUT | Number of Modules in Series |
| dc_string_voltage | Maximum DC String Voltage | OUTPUT | Maximum DC String Voltage |
Calculation Steps
- Enter the open-circuit voltage at stc in V.
- Enter the temperature coefficient of voc in V/°C.
- Enter the record low ambient temperature in °C.
- Enter the stc temperature in °C.
- Enter the number of modules in series in 1.
- Step 1: Compute maximum dc string voltage.
- Read the maximum dc string voltage (V) from the results.
Engineering Summary
Calculate NEC 690.7(c) PV String Voltage Correction for Lowest Expected Ambient Temperature
Frequently Asked Questions
What does this calculator calculate?
The NEC 690.7(c) PV String Voltage Correction for Lowest Expected Ambient Temperature calculator estimates Maximum DC String Voltage based on the input parameters you provide
Why is open-circuit voltage at stc important in this calculation?
open-circuit voltage at stc is directly proportional to maximum dc string voltage. When you enter open-circuit voltage at stc in V, the calculator uses it in the engineering formula to compute the output
How should I interpret the result maximum dc string voltage?
The calculator outputs maximum dc string voltage in V. The result is computed directly from the input values using the defined engineering formula
What units should I use for the inputs?
Enter each value in the units shown next to the input field: Open-Circuit Voltage at STC (V), Temperature Coefficient of Voc (V/°C), Record Low Ambient Temperature (°C), STC Temperature (°C). Make sure all inputs use the specified units for consistent results
What assumptions does this calculator use?
This calculator uses automatically validated engineering formulas. Results are approximate and should be validated against site-specific conditions, applicable codes, and professional engineering judgment
Related Tools
PV String Voltage Sag Under High-Temperature & Low-Irradiance Conditions Validator Calculator
Battery Pack Series-String Current Imbalance Estimator (Interconnect Resistance Variation) calculator
Coulombic Efficiency-Adjusted Battery Charging Time calculator
PV Module Temperature Coefficient Derated Power Output Calculator
Solar Off-grid Battery Bank Capacity Sizing for Daily Autonomy calculator
Combiner Box DC Arc-Fault Risk Index with Rapid Shutdown Compliance Factor calculator
Browse More Tools
Explore the full index of engineering calculators on this vertical site.